![]() ![]() For example, if AC power is lost, the system battery will become drained, prompting the system to send out the low battery alert to your control panel. It’s common for the battery for your system to become drained for many different reasons. If not, allow the new battery to charge for up to 24 hours, and if necessary, perform the walk-test again.The keypad for your Honeywell VISTA home security system may display a low battery alert message if the sealed acid battery located inside of your alarm cabinet becomes compromised. If the battery passed the load test, the low battery message should clear with this disarm. After about five (5) minutes, enter the Installer Code, Master Code, or Partition Master Code + Off. The keypad will emit a single beep every 40 seconds as a reminder that the system is in walk-test mode. Leave the panel in walk-test mode for approximately five (5) minutes. Be aware the external siren will sound for approximately two (2) seconds as part of the load test. Enter Installer Code, Master Code, or Partition Master Code + +. Be sure the panel is disarmed with no faults. If it did not pass and the battery is new, allow it to charge for up to 24 hours. If the battery passed the load test, the low battery condition will clear when test mode is exited. The panel will exit test mode on its own after four (4) hours if the user forgets to exit. To exit the walk-test, enter the Installer Code, Master Code, or Partition Master Code + Off. Once the panel is in walk-test mode, allow it to stay that way for about five (5) minutes. An alpha keypad will display "Test in Progress", and the keypad will emit a single beep every 40 seconds to remind the user that the panel is in test. Be aware that as part of the load test, the siren will sound for about two (2) seconds. At the keypad, enter the Installer Code, Master Code, or Partition Master Code + +. In order to perform a walk-test, the system must be ready. Another way is to force a load test of the battery. In some cases, the new battery may need a bit longer to charge, so a low battery message may persist for up to 24 hours before it will clear on its own. One is to replace the existing battery, verify that AC power is present, and then wait for up to four (4) hours for the panel to run its usual load test. There are two ways to load test a battery. One of these two batteries can usually replace the existing bad battery. When this begins to happen, it is best to replace the battery and avoid the annoyance. This will result in multiple low battery warnings, followed low battery restore conditions. An older battery may fail, then pass the load test for some time before failing completely. ![]() When a low battery condition is caused by a failed load test, it requires that the battery pass a load test to clear the low battery display. This is because the existing battery is beginning to fail the panel's load test. When the battery starts to fail, users will see low battery messages on the keypad, even when there has been no AC loss. Depending on how often the panel must run on battery power, the panel's battery will last around three (3) to five (5) years. When AC power is lost, the battery then takes over to provide the necessary current to power the panel until AC power is returned. When AC power is present, the panel provides a trickle charge to the battery. A low battery trouble will not prevent the panel from being armed.Ī Vista P-Series Alarm Panel uses a 12-Volt Lead-Acid Battery. The trouble beep can be silenced by entering any valid 4-digit code, plus Off. If the battery fails either of these tests, a low battery message will be displayed on the keypad, along with a rapid trouble beep. In addition, every four (4) hours the panel does a two (2) minute load test to verify that the battery is capable of supporting the panel load in the event of an AC loss. Every three (3) minutes, the panel checks to verify that a battery is present and connected to the system. Enter walk test mode by pressing Installer Code + 5 + 0.Ī Vista P-Series Alarm Panel supervises its battery in two ways. The easiest way to do this is with a walk-test. Do this by demonstrating to the panel that the battery is present and that it will hold up under load. To clear a low battery display, you must first clear the low battery condition. Clearing a Low Battery On a Vista P Series Panel ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |